Last Modified: 11-29-2007 |
1.6 G |
|
Service Category: Power Source/Network |
Section: Battery/Charging |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM00000188X01GX |
|
Title: 3UR-FE BATTERY / CHARGING: GENERATOR: INSPECTION (2008 Sequoia) |
INSPECTION
1. INSPECT GENERATOR ROTOR ASSEMBLY
|
(a) Check the rotor for an open circuit.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
130 A Type
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Slip ring - Slip ring
|
20°C (68°F)
|
2.3 to 2.7 Ω
|
150 A Type
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Slip ring - Slip ring
|
20°C (68°F)
|
1.5 to 1.9 Ω
|
180 A Type
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Slip ring - Slip ring
|
20°C (68°F)
|
1.4 to 1.8Ω
|
If the result is not as specified, replace the rotor assembly.
|
|
(b) Check if the rotor is grounded.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Slip ring - Rotor
|
Always
|
10 kΩ or higher
|
If the result is not as specified, replace the rotor assembly.
|
(c) Check that the slip rings are not rough or scored.
If rough or scored, replace the rotor assembly.
|
(d) Using a vernier caliper, measure the slip ring diameter.
Standard diameter:
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter:
14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the rotor assembly.
|
2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
(a) Using a vernier caliper, measure the exposed brush length.
Standard exposed length:
10.5 mm (0.413 in.)
Minimum exposed length:
4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the brush holder assembly.
3. INSPECT GENERATOR DRIVE END FRAME BEARING
|
(a) When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.
If necessary, replace the bearing.
|
4. INSPECT GENERATOR ROTOR BEARING
|
(a) When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.
If necessary, replace the generator rotor.
|
|